Electric air-conditioning systems driven by electricity from a wind turbine can be defined as wind electric and cooling systems according to the definition of solar-activated air-conditioners. They can potentially contribute to reduce primary energy demand and CO2 emission in the civil sector. In this paper, mini wind turbines are considered coupled with a ground source heat pump in order to serve an office building for air-conditioning and supply the electricity surplus for the pure electric load of the user. Different plant configurations are considered. First of all, assessments with two kinds of wind turbines (5-5.5 kW), vertical and horizontal axis, are performed, also considering the coupling with one and two identical wind generators. Secondly, to better use on-site electricity, a parametric study is proposed taking into account different battery storage system sizes (3.2-9.6 kWh). Finally, the plant is simulated in two locations: Naples and Cagliari. Simulation results demonstrate that the source availability mainly affects the system performance. In Cagliari, the primary energy reduction per kWh of final energy demand (for pure electric load, space heating, and cooling) is equal to 1.24, 54.8% more than in Naples. In addition, the storage system limits the interaction with the power grid, lowering the exported electricity from about 50% to about 27% for Naples and from 63% to 50% for Cagliari. The fraction of the load met by renewable energy accounts for up to 25% for Naples and 48% for Cagliari.

A wind electric-driven combined heating, cooling, and electricity system for an office building in two Italian cities y

Tariello F.
2020-01-01

Abstract

Electric air-conditioning systems driven by electricity from a wind turbine can be defined as wind electric and cooling systems according to the definition of solar-activated air-conditioners. They can potentially contribute to reduce primary energy demand and CO2 emission in the civil sector. In this paper, mini wind turbines are considered coupled with a ground source heat pump in order to serve an office building for air-conditioning and supply the electricity surplus for the pure electric load of the user. Different plant configurations are considered. First of all, assessments with two kinds of wind turbines (5-5.5 kW), vertical and horizontal axis, are performed, also considering the coupling with one and two identical wind generators. Secondly, to better use on-site electricity, a parametric study is proposed taking into account different battery storage system sizes (3.2-9.6 kWh). Finally, the plant is simulated in two locations: Naples and Cagliari. Simulation results demonstrate that the source availability mainly affects the system performance. In Cagliari, the primary energy reduction per kWh of final energy demand (for pure electric load, space heating, and cooling) is equal to 1.24, 54.8% more than in Naples. In addition, the storage system limits the interaction with the power grid, lowering the exported electricity from about 50% to about 27% for Naples and from 63% to 50% for Cagliari. The fraction of the load met by renewable energy accounts for up to 25% for Naples and 48% for Cagliari.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11695/92325
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact