Many studies show that particle toxicity increases with decreasing their size, emphasizing the role of submicrometric particles, in particular of ultrafine particles (<100 nm). In fact, particles greater than 2.5 μm are quickly removed through dry and wet deposition on the timescale of hours whereas submicrometer particles may reside in atmosphere for weeks, penetrate in indoor environment, and be long-range transported. High aerosol size resolution measurements are important for a correct assessment of the deposition efficiency in the human respiratory system, and time resolution is another important requisite. Starting from such considerations, time-resolved aerosol particle number size distributions have been measured in downtown Rome. Fast Mobility Particle Sizer (FMPS) and Scanning Mobility Particle Sizer (SMPS) measurements have been carried out at the INAIL’s Pilot Station, located in downtown Rome, in an area characterized by high density of autovehicular traffic. The two instruments have allowed to investigate deeply the urban aerosol in the range of 5.6–560 and 3.5–117 nm, respectively. In particular, the FMPS measurements have confirmed the interpretation about the transition phenomena in the time interval of few seconds, timescale typically associated with the emission of gasoline and diesel engines. In downtown Rome, the hourly average size distribution is bimodal or trimodal with maxima at about 5–15, 20–30, and 70–100 nm. Particle formation in the nucleation mode was associated to freshly emitted autovehicular exhaust.

Dynamic of submicrometer particles in urban environment

AVINO P
;
2017-01-01

Abstract

Many studies show that particle toxicity increases with decreasing their size, emphasizing the role of submicrometric particles, in particular of ultrafine particles (<100 nm). In fact, particles greater than 2.5 μm are quickly removed through dry and wet deposition on the timescale of hours whereas submicrometer particles may reside in atmosphere for weeks, penetrate in indoor environment, and be long-range transported. High aerosol size resolution measurements are important for a correct assessment of the deposition efficiency in the human respiratory system, and time resolution is another important requisite. Starting from such considerations, time-resolved aerosol particle number size distributions have been measured in downtown Rome. Fast Mobility Particle Sizer (FMPS) and Scanning Mobility Particle Sizer (SMPS) measurements have been carried out at the INAIL’s Pilot Station, located in downtown Rome, in an area characterized by high density of autovehicular traffic. The two instruments have allowed to investigate deeply the urban aerosol in the range of 5.6–560 and 3.5–117 nm, respectively. In particular, the FMPS measurements have confirmed the interpretation about the transition phenomena in the time interval of few seconds, timescale typically associated with the emission of gasoline and diesel engines. In downtown Rome, the hourly average size distribution is bimodal or trimodal with maxima at about 5–15, 20–30, and 70–100 nm. Particle formation in the nucleation mode was associated to freshly emitted autovehicular exhaust.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11695/73315
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 7
social impact