Andreas Nikolis,1 Doria Grimard,2 Yves Pesant,3 Giovanni Scapagnini,4 Denis Vézina5 1Division of Plastic Surgery, Victoria Park Research Centre, Montreal, 2Q&T Research Chicoutimi, Chicoutimi, 3St-Jerome Medical Research Inc., St-Jerome, Quebec, Canada; 4Department of Medicine and Health Sciences, School of Medicine, University of Molise, Campobasso, Italy; 5Klox Technologies, Laval, Quebec, Canada Purpose: To investigate the safety and efficacy of the BioPhotonic System developed by Klox Technologies in a case series of ten patients with venous leg ulcers.Patients and methods: Ten patients with chronic venous leg ulcers, having failed on at least one previous therapy, were enrolled into this case series.Results: Nine patients were evaluable for efficacy. A response (defined as decrease in wound surface area) was observed in seven patients (77.8%). Of these, four patients (44.4%) achieved wound closure on average 4 months (127.5 days) following the beginning of the treatment. Two patients did not respond to the investigational treatment. Quality of life improved over time throughout the study. Compliance was excellent, with 93.2% of visits completed as per protocol. Safety was unremarkable, with only four treatment-emergent-related adverse events, for which no specific intervention was required.Conclusion: The BioPhotonic System was shown to be safe and extremely well tolerated. It also demonstrated potential in terms of wound closure, wound surface area decrease, and wound bed preparation. Keywords: biophotonics, light, photobiomodulation, venous leg ulcers
A prospective case series evaluating the safety and efficacy of the Klox BioPhotonic System in venous leg ulcers
SCAPAGNINI, Giovanni;
2016-01-01
Abstract
Andreas Nikolis,1 Doria Grimard,2 Yves Pesant,3 Giovanni Scapagnini,4 Denis Vézina5 1Division of Plastic Surgery, Victoria Park Research Centre, Montreal, 2Q&T Research Chicoutimi, Chicoutimi, 3St-Jerome Medical Research Inc., St-Jerome, Quebec, Canada; 4Department of Medicine and Health Sciences, School of Medicine, University of Molise, Campobasso, Italy; 5Klox Technologies, Laval, Quebec, Canada Purpose: To investigate the safety and efficacy of the BioPhotonic System developed by Klox Technologies in a case series of ten patients with venous leg ulcers.Patients and methods: Ten patients with chronic venous leg ulcers, having failed on at least one previous therapy, were enrolled into this case series.Results: Nine patients were evaluable for efficacy. A response (defined as decrease in wound surface area) was observed in seven patients (77.8%). Of these, four patients (44.4%) achieved wound closure on average 4 months (127.5 days) following the beginning of the treatment. Two patients did not respond to the investigational treatment. Quality of life improved over time throughout the study. Compliance was excellent, with 93.2% of visits completed as per protocol. Safety was unremarkable, with only four treatment-emergent-related adverse events, for which no specific intervention was required.Conclusion: The BioPhotonic System was shown to be safe and extremely well tolerated. It also demonstrated potential in terms of wound closure, wound surface area decrease, and wound bed preparation. Keywords: biophotonics, light, photobiomodulation, venous leg ulcersI documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.