To investigate the in vivo ablation characteristics of a microwave ablation antenna in the livers of humans with tumors, a retrospective analysis of the ablation zones was conducted after applying Emprint microwave ablation systems for treatment. Percutaneous microwave ablations performed between January 2022 and September 2022 were included in this study. Subsequently, immediate post-ablation echography images were subjected to retrospective evaluation to state the long ablated diameter, short ablated diameter, and volume. The calculated ablation lengths and volume indices were then compared between in vivo and ex vivo results obtained from laboratory experiments conducted on porcine liver. The ex vivo data showed a good correlation between energy delivered and both increasing ablated dimensions (both p < 0.001) and volume (p < 0.001). The in vivo data showed a good correlation for dimensions (p = 0.037 and p = 0.019) and a worse correlation for volume (p = 0.142). When comparing ex vivo and in vivo data for higher energies, the ablated volumes grew much more rapidly in ex vivo cases compared to in vivo ones. Finally, a set of correlations to scale ex vivo results with in vivo ones is presented. This phenomenon was likely due to the absence of perfusion, which acts as a cooling system.

Emprint Microwave Thermoablation System: Bridging Thermal Ablation Efficacy between Human Patients and Porcine Models through Mathematical Correlation

Cafarchio, Andrea;Brunese, Maria Chiara;Rocca, Aldo;
2023-01-01

Abstract

To investigate the in vivo ablation characteristics of a microwave ablation antenna in the livers of humans with tumors, a retrospective analysis of the ablation zones was conducted after applying Emprint microwave ablation systems for treatment. Percutaneous microwave ablations performed between January 2022 and September 2022 were included in this study. Subsequently, immediate post-ablation echography images were subjected to retrospective evaluation to state the long ablated diameter, short ablated diameter, and volume. The calculated ablation lengths and volume indices were then compared between in vivo and ex vivo results obtained from laboratory experiments conducted on porcine liver. The ex vivo data showed a good correlation between energy delivered and both increasing ablated dimensions (both p < 0.001) and volume (p < 0.001). The in vivo data showed a good correlation for dimensions (p = 0.037 and p = 0.019) and a worse correlation for volume (p = 0.142). When comparing ex vivo and in vivo data for higher energies, the ablated volumes grew much more rapidly in ex vivo cases compared to in vivo ones. Finally, a set of correlations to scale ex vivo results with in vivo ones is presented. This phenomenon was likely due to the absence of perfusion, which acts as a cooling system.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11695/128709
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact